ESR Series Valve Terminal в ГК СПТ

ESR Series Valve Terminal
How to order?

Order Example:

1.Same valve: ES Fieldbus Valve Terminal, 1 series,O-Link, 16 outputs,6pcs 5/2 single control RV5211port size 1/8”,DC24V,without accessories,G thread, The ERP code is ES1R-LK16-6S-06E4.

2,Mixed different valves: ES Fieldbus Valve Terminal, 1 series.lO-Link,16 outputssee right picture: station 1 & station 2 are 5/3 center closed SR5312C, station 3 & station 4are 5/2 double control SR5212, station 5 & station 6 & station 7 are 5/2 single control RV5211.port size 1/8”,DC24V, with DIN guide railclip and 1M guide rail, G thread.The ERP codeis ES1R-LK16-CD3S-06E4-D.

Specifications
Model ES1R-LK16
ES2R-LK16
Output 16
Protocols lO-Link
Baud rate COM2(38.4kbps)
Configuration files IODD file
Specification version V1.1(Compatible withV1.0)
Control power supply Voltage DC24V(DC21.6~26.4V)
Current consumption 15mA below
Output power voltage(valve) DC24V(DC22.8~26.4V)
Interface M12,5pin,Acode
Interface type B class
Device diagnosis System diagnosis, communication error, short circuit protection
Protection IP65
Storage temperature -20~70℃
Working temperature -10~50℃
Interface

Interface(M12,code A, Class B)

Pin Type Description
1 PS24 Control working voltage+24V
2 PL24 Working voltage of load valve+24V
3 PSo Control working voltage OV
4 C/Q Data communication(IO-Link)
5 PLO Working voltage of load valve OV

 

LED Indicators
Indicators Status Meaning
X1 LED close Abnormal power supply
Green open Normal power supply, no communication established
Red open Fault or abnormalload power supply
Green Flash Normal working