ESR Series Valve Terminal
Заказать
How to order?
Order Example:
1.Same valve: ES Fieldbus Valve Terminal, 1 series,O-Link, 16 outputs,6pcs 5/2 single control RV5211port size 1/8”,DC24V,without accessories,G thread, The ERP code is ES1R-LK16-6S-06E4.
2,Mixed different valves: ES Fieldbus Valve Terminal, 1 series.lO-Link,16 outputssee right picture: station 1 & station 2 are 5/3 center closed SR5312C, station 3 & station 4are 5/2 double control SR5212, station 5 & station 6 & station 7 are 5/2 single control RV5211.port size 1/8”,DC24V, with DIN guide railclip and 1M guide rail, G thread.The ERP codeis ES1R-LK16-CD3S-06E4-D.
Specifications
Model | ES1R-LK16 ES2R-LK16 |
|
Output | 16 | |
Protocols | lO-Link | |
Baud rate | COM2(38.4kbps) | |
Configuration files | IODD file | |
Specification version | V1.1(Compatible withV1.0) | |
Control power supply | Voltage | DC24V(DC21.6~26.4V) |
Current consumption | 15mA below | |
Output power voltage(valve) | DC24V(DC22.8~26.4V) | |
Interface | M12,5pin,Acode | |
Interface type | B class | |
Device diagnosis | System diagnosis, communication error, short circuit protection | |
Protection | IP65 | |
Storage temperature | -20~70℃ | |
Working temperature | -10~50℃ |
Interface
Interface(M12,code A, Class B)
Pin | Type | Description |
1 | PS24 | Control working voltage+24V |
2 | PL24 | Working voltage of load valve+24V |
3 | PSo | Control working voltage OV |
4 | C/Q | Data communication(IO-Link) |
5 | PLO | Working voltage of load valve OV |
LED Indicators
Indicators | Status | Meaning |
X1 | LED close | Abnormal power supply |
Green open | Normal power supply, no communication established | |
Red open | Fault or abnormalload power supply | |
Green Flash | Normal working |
Wiring
Wiring Diagram
Precautions for Use
Main Dimension